- MS4110 is an example of an oil debris monitoring system
- OODM cannot predict failure
- Only gives data on wear particle generation rate
- Correlating wear particle generation to failure is system-specific
- Metalscan system can isolate ferrous and non-ferrous
- Chipcheck system can also identify alloys of the metal using spectroscopy
- M50 is bearing grade steel
- If detected, don't use the machine
- Silver is used as coatings for the bearings
- Silver in oil indicates superficial damage
- Ferrous particles are detected using eddy current
- Nonferrous particles are detected using permeability-based detection
- Usually, opposite phase signals are obtained for ferrous and non-ferrous
- The only parameter on the sensor is the phase angle
- The interquartile demodulation technique is used to detect the chips.
- Data communication is through Modbus or TCP protocol